KSB Ama Porter group pumps belong to drainage pumps – contaminated water.
Application:
drainage installations
water intake
drying
Pumped media
contaminated water
wastewater with fibrous and solid particles
fluids including gases
The repaired pump Ama Porter 500 ND is equipped with a synchronous, induction three-phase motor without the float valve and a free flow rotor (F rotor).
DESCRIPTION OF THE SCOPE OF PERFORMED MODERNIZING WORK
After dismantling the pump from the workstation, the following operations were performed:
- cleaning hydraulic elements of the pump,
- technical verification of the rotor and shaft,
- performing motor and oil chamber overpressure tests,
- electrical measurements of pump cabling,
- rewinding the electric engine,
- replacement of mechanical sealing,
- replacement of sealing,
- replacement of O-rings,
- replacement of motor bearings,
- pump painting,
- checking the front joint,
- inspection of pump shaft rotation slack,
- pump test on the test bench
![]()
![]()
![]()
![]()