KSB AMA-Porter500 ND PUMP

KSB Ama Porter group pumps belong to drainage pumps – contaminated water.

KSB Ama Porter group pumps belong to drainage pumps – contaminated water.

Application:
drainage installations
water intake
drying
Pumped media
contaminated water
wastewater with fibrous and solid particles
fluids including gases
The repaired pump Ama Porter 500 ND is equipped with a synchronous, induction three-phase motor without the float valve and a free flow rotor (F rotor).

DESCRIPTION OF THE SCOPE OF PERFORMED MODERNIZING WORK

After dismantling the pump from the workstation, the following operations were performed:

  • cleaning hydraulic elements of the pump,
  • technical verification of the rotor and shaft,
  • performing motor and oil chamber overpressure tests,
  • electrical measurements of pump cabling,
  • rewinding the electric engine,
  • replacement of mechanical sealing,
  • replacement of sealing,
  • replacement of O-rings,
  • replacement of motor bearings,
  • pump painting,
  • checking the front joint,
  • inspection of pump shaft rotation slack,
  • pump test on the test bench